Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 131(2): 251.e1-251.e7, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38368000

RESUMO

STATEMENT OF PROBLEM: Little is known about the effect of different composite resin cements on the bond strength of prefabricated and milled glass fiber post-and-cores. PURPOSE: The purpose of this in vitro study was to compare the push-out bond strengths of root dentin and standard, relined, or computer-aided design and computer-aided manufacturing (CAD-CAM) glass fiber post-and-cores luted with conventional, universal, or self-adhesive composite resin cement. MATERIAL AND METHODS: Post spaces were prepared in 90 premolars. Standard and relined prefabricated and CAD-CAM-milled glass fiber post-and-cores were luted with conventional (RelyX ARC; 3M ESPE), universal (RelyX Ultimate; 3M ESPE), and self-adhesive (RelyX U200; 3M ESPE) composite resin cement (n=10). All specimens were thermally aged (5000 cycles at 5°C and 55°C with a 20-second dwell time) and mechanical fatigue (1 000 000 cycles at 2 Hz, 50-N load). The specimens were sectioned perpendicularly to the root long axis into 1-mm-thick sections (apical, middle, and cervical root thirds), the push-out bond strength was determined, and the mode of failure recorded. Data were submitted to the Kruskal-Wallis test followed by the Bonferroni-Dunn multiple comparison test (α=.05). RESULTS: Push-out bond strength values did not differ (P>.05) among posts at the same root thirds. Standard posts showed higher bond strength than CAD-CAM at the apical third for data grouped by composite resin cements (P<.001). The cervical root thirds had higher bond strength than the apical thirds (P<.05). The cervical, middle, and apical root thirds showed decreasing bond strength values for each type of post for data grouped by composite resin cement (P<.001). Adhesive failures at the dentin-cement interface were predominant. CONCLUSIONS: The type of posts and cements did not affect the bond strength of glass fiber posts. The cervical root thirds had better bonding performance than the apical thirds.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Resinas Compostas/uso terapêutico , Cimentos de Resina/uso terapêutico , Cimentos de Resina/química , Vidro , Cimentos de Ionômeros de Vidro , Desenho Assistido por Computador , Teste de Materiais , Dentina , Cavidade Pulpar , Análise do Estresse Dentário
2.
J Conserv Dent ; 21(4): 455-458, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30122831

RESUMO

The use of digital tools offers a new perspective to daily clinical activities. The digital information serves as a starting point for a wax-up and intraoral mock-up, which is widely reported in literature as an objective and efficient communication tool among dentist, patient, and technician. This case report of a maxillary anterior rehabilitation demonstrates esthetic planning with the digital smile design (DSD) system and a direct mock-up technique. After preoperative photographs were obtained, digital planning was created using DSD. However, due to differences in virtual simulation, a direct mock-up with composite resin was performed. Porcelain laminate veneers using feldspathic ceramics were used to restore the anterior teeth. Many times, the DSD simulation is not enough for the patient to understand and observe the changes that will be performed on the anterior teeth. This combination of techniques can offer predictability to results as well increasing the patient expectation satisfaction.

3.
J Clin Exp Dent ; 10(6): e591-e597, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29930778

RESUMO

BACKGROUND: There is no ideal protocol for the surface treatment of fiber posts, especially when using a computer-aided design/computer-aided manufacturing (CAD/CAM) experimental fiberglass block. The purpose of this study was to evaluate the bond strength of a CAD/CAM customized glass fiber post and core after applying different surface treatment techniques. MATERIAL AND METHODS: Forty premolars were prepared to receive a customized CAD/CAM glass-fiber post and core obtained from an experimental block of glass fiber and epoxy resin. The specimens were randomly distributed in 4 groups (n=10) according to the post and core surface treatment: ETH - 70% ethanol; HP - 24% hydrogen peroxide for 1 minute; ETH/S - 70% ethanol + silane; HP/S - 24% hydrogen peroxide + silane. The universal adhesive containing silane was applied on the posts and prepared post spaces in all groups. The posts were cemented using dual cure resin cement. The specimens were stored in distilled water at 37°C for 24 h, cut (two slices of 1 mm for each root third - coronal, middle, and apical) and subjected to push-out test (0.5 mm/min). Data was subjected to two-way ANOVA (surface treatment and root third) and Tukey's test (α=0,05). RESULTS: There was no significant difference of bond strength values among groups, regardless the surface treatment (p >0.05). There was significant difference on bond strength values for the different root thirds (p<0.05) (coronal>middle=apical). CONCLUSIONS: The different surface treatment and application of additional silane in the CAD/CAM customized glass-fiber post and core does not interfere on bond strength values. The root dentin third interfered on the bond strength, with higher values for the coronal third. Key words:Post and core technique, cad/cam, shear strength, hydrogen peroxide.

4.
J Prosthet Dent ; 120(2): 242-245, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29475760

RESUMO

Customization of post-and-cores using computer-aided design and computer-aided manufacturing (CAD-CAM) requires the scanning of a pattern and the subsequent digital design. This technique describes a method of fabricating a CAD-CAM-customized post-and-core designed from a scanned polyvinyl siloxane impression and milled from a nanoparticle/nanocluster-filled resin block. The polyvinyl siloxane impression allowed a faster and more efficient customization of the CAD-CAM post-and-core than a conventional acrylic resin pattern. The properties of the nanoparticle/nanocluster filled resin block make the material suitable for chairside CAD-CAM post-and-core fabrication.


Assuntos
Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária/métodos , Cavidade Pulpar , Técnica para Retentor Intrarradicular , Adulto , Dente Pré-Molar , Cerâmica , Técnica de Fundição Odontológica , Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica , Porcelana Dentária/química , Feminino , Humanos , Maxila , Nanopartículas , Polivinil , Tratamento do Canal Radicular , Siloxanas
5.
Am J Dent ; 30(1): 3-8, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-29178707

RESUMO

PURPOSE: To investigate the fracture resistance of weakened roots restored with prefabricated or CAD/CAM-customized posts and cores as well as the thickness of the cement film and the presence of voids in the cement. METHODS: The roots of 40 human premolars were weakened by removing internal dentin with a diamond bur (2.5 mm in the coronal third and 1.5 mm in the apical third) and restored with prefabricated posts (PPs) or customized posts (CPs) with or without a zirconia crown (n= 10). Posts and crowns were cemented with resin cement. Microtomography was used to determine the thickness of the cement film and whether voids were present. After fatigue testing (1 million cycles, 50 N, 5 Hz, 36.5°C), the specimens underwent compression testing with an oblique load (30°, 1 mm/minute) and fracture strengths were recorded (N). Fracture strength and film thickness were analyzed with ANOVA and the Games-Howell test; the variable presence of voids was analyzed with the Mann-Whitney test (α= 5%). RESULTS: Mean fracture strengths varied between 640.4 and 792.9 N and did not differ significantly between groups. The CP group had a thinner cement film and fewer voids than the PP group. There was a positive, statistically significant correlation (Spearman, R=0.488, P= 0.029) between these variables. CLINICAL SIGNIFICANCE: CAD/CAM-manufactured glass-fiber posts and cores do not affect the fracture strength of flared root canals or cause catastrophic failure of the root when used with zirconia crowns.


Assuntos
Desenho Assistido por Computador , Técnica para Retentor Intrarradicular/instrumentação , Tratamento do Canal Radicular , Fraturas dos Dentes/prevenção & controle , Coroas , Cimentos Dentários/química , Materiais Dentários/química , Análise do Estresse Dentário , Vidro/química , Humanos , Técnicas In Vitro , Dente Molar , Raiz Dentária , Zircônio/química
6.
Eur J Dent ; 5(1): 107-12, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21228960

RESUMO

Customized glass fiber posts that is well adjusted into the root canal and have mechanical properties similar to those of dentin may be a suitable treatment for severely compromised endodontically treated teeth. This article reports a 3-year follow up of severely damaged endodontically treated teeth restored with unidirectional fiber glass customized post and core system instead of a conventional fiber post. The fabrication of this glass fiber customized post is a simple technique, providing an increased volume of fibers into the root canal, and an adequate polymerization of the post-core system. Over a three-year period, the treatments demonstrated good clinical and radiographic characteristics, with no fracture or loss of the post and/or crown. This technique can be considered effective, less invasive, and suitable for restore endodontically treated teeth.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...